  Datasheet File OCR Text:
 S/TRI/SGT965960/B/7/05/2002
page 1 / 2 F/GB
Relais Statique Triphase Three Phase Solid State Relays
* Sortie AC pour charge resistives. * Commande 90-240 VAC avec LED. * Possibilite de protection IP10 en option:Capot 1K199 000. * AC output for resistive loads. * 90-240 VAC control voltage with LED. * Protection IP10 optional (1K199 000).
SGT965960
24 to 600 VAC - 50 ARMS
Dimensions / Dimensions:
Application typique /Typical application:
R S T R S T R S T
Circuit equivalent/Equivalent circuit :
1L1
39,5
Adaptateur / Adapter
LED 2T1 3L2
82,7 19 19
A1 = A2
Resistive or inductive load
Adaptateur / Adapter
M
4T2 5L3
4,4
A2
1L1
3L2
5L3
A1 2T1 4T2 6T3
58,4
73,5
23
Adaptateur / Adapter
40
6T3
91 100
Caracteristiques de commande (a 20C) / Control characteristics (at 20C) Parametre / Parameter Tension de commande / Control voltage Courant de commande / Control current (@ Uc ) Tension de relachement/Release voltage Resistance interne / Input internal resistor fig.1 Tension inverse / Reverse voltage Symbol Uc Ic Uc off Rc Urv Min 90 4 4 AC Nom Max 240 11 Unit V mA V K V VRMS VRMS V
fig. 1 :Caracteristique d'entree / Control characteristic
15 10 5 0 0 50 100 150 200 250 Uc (V)
21
Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Ui 4000 Isolement sortie-semelle/Output-case isolation @500m Ui 3300 Tension assignee isolement/ Rated impulse voltage Uimp 4000 Caracteristiques generales / General characteristics Parametre / Parameter Poids/Weight Plage de temperature de stockage / Storage temperature range Plage de temperature de fonctionnement/Operating temperature range
Conditions
Symbol
Ic (mA)
Typ. 370 -40 / +100 -40 / +100
Unit g C C
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
celduc
r e l a i
s
S/TRI/SGT965960/B/7/05/2002
Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parametre / Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC-51/ AC-51 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite conduite / Conducted immunity level EMC Test d'immunite conduite / Conducted immunity level Conformite / Conformity Caracteristiques thermiques / thermal curves :
220 200 180 160 Total wasted power (W) 140 120 100
page 2 / 2 F/GB
Conditions Symbol Ue Uemin-max Up Usync Ua Ie AC-51 Itsm Vd Ilk Ie min ton max toff max f dv/dt di/dt I2t Typ. 400 24-600 1200 24 10 50 Unit V rms V rms V V V A rms
Ie nom ( see Fig. 2 ) tp=10ms (Fig. 3) @ Ie nom @Ue, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz
IEC 1000-4-4 (burst) IEC 1000-4-5(schocks) EN60947-4-x
550 A 1,4 V 1 mA 5 mA 10 ms 10 ms 10-440 Hz 500 V/s 50 A/s 1500 A2s 2kV criterion A 2kV crit.A with external VDR
Full on-state
0,3K/W
0,55K/W
0,95K/W 80 60 40 20 0 without heatsink 1,2K/W
Fig.3 Courbes de surcharge de courant / Overload current curves
05
10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90 100 RMS load current (A) Ambient temperature (C)
Surge current Itsm (A peak) = f(t) 600 Itsm (Apeak)
for models with Itsm =550A
No repetitive Itsm (Apeak)=f(t) without voltage reapplied
400
1 -Itsm non repetitif sans tension reappliquee est donne pour la determination des protections. No repetitive Itsm is given without voltage reapplied for the determination of the protection. 2 -Itsm repetitif est donne pour des surcharges de courant (Tj initiale=70C). La repetition de ces surcharges de courant diminue la duree de vie du Relais. Repetitive Itsm is given for inrush current with initial Tj = 70C. The repetition of the surge current decrease the lifetime SSR's .
200
Repetitive Itsm (Apeak)=f(t) with voltage reapplied for initial Tj =70C
0
0,01
0,1
t (s)
1
10
Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge.
Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains.
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 